- Contact Person : Ms. Lee Ivy
- Company Name : Changsha Kaiyuan Instruments Co., Ltd.
- Tel : 86-731-84021617
- Fax : 86-731-84066915
- Address : Hunan,Changsha,No.172 Kaiyuan Road, Changsha Economic & Technological Development Zone,Changsha, P. R. China
- Country/Region : China
- Zip : 410100
Carbon Sulfur Analyzer
♦ Application
5E-CS400 employs high-frequency induced combustion to determine total carbon and total sulfur content in steel, iron, alloy, nonferrous metal, cement, mineral, soil, ceramics, glass and other materials.
♦ Specififcation
Analysis method | Infrared spectroscopy |
Resolution | 0.1ppm |
Analysis range | C: 0.0001%~8% (expansible) S: 0.0001%~3% (expansible) |
Repeatability | C: RSD ≤0.5% S: RSD ≤1.5% |
Analysis time | 20 s~50 s, representative value: 30 s |
High frequency furnace | 18 MHz, 2.5 kW |
Sample mass | Iron:0.2000g Steel:0.4000g |
Ambient condition | Room temperature 5°C~35°C; relative humidity ≤85%, no corrosive gas and violent vibration. |
Power supply | AC220V, 50Hz, 5000W. |
Oxygen gas | O2: purity ≥99.5%, pressure 0.30 Mpa, Oxygen-carrying pressure of furnace end 0.08Mpa. |
Power Gas | Nitrogen or compressed air (purified); pressure imported 0.30 Mpa. |
Analysis gas flow | 3.5L/min. |
Dimension | 600 mm (length)× 700 mm (width) × 860 mm (height) |
♦ Features
Discharge ash automatically using back flushing technique, it is not necessary to clean furnace end manually after thousands of analysis.Detect gas circuit by sector which is convenient to check the position leaking.Bi-carbon cell structure; wider measuring range, better linearity; select appropriate cell automatically when analyzing.Original wide-range single sample calibrating with calibrating factors: Widen calibrating curve using range and reduce calibrating frequency.Original comparison level automatic selection; wider analysis range, samples with high content or low content can be analyzed by same method.Start the analysis by “Start analysis” button without mouse or keyboard, operation is more convenient.Power:0~100% (adjustable), which is applicable to different sample.Remove adsorptions, no "saturation" of gas circuit after powering on; Both interval measuring (bath analysis) and continuous measuring (product analysis) are stable.Brevity software interface and easy operation; Statistical data (average value, range, deviation and RSD) will be out if sample is selected; Display thickness curve at real time, inquire at any time. Connect to balance without manual input.Connect with electric balance; input sample mass automatically without keyboard and mouse.Carbon Sulfur Analyzer